Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
Indian J Cancer ; 2018 Jan; 55(1): 9-15
Article | IMSEAR | ID: sea-190339

ABSTRACT

Introduction: There is paucity of data from India about the outcomes of patients with various hematological malignancies. Since its formation in 2009, the adult hematolymphoid disease management group of the Tata Memorial Centre is dedicated to the treatment of hematological malignancies alone. In this report, we present the outcomes of patients treated at our centre over a 5 year period for various haematological malignancies in both transplant and non-transplant setting. Methods: This is a retrospective analysis of all patients registered in adult hematolymphoid disease management group between 1st January 2010 to 31st December 2014. Patients not treated at our centre were excluded from survival analysis. The cut off date for survival analysis was 31st January 2016. Results: Overall, 1869, 3633 and 544 patients with acute leukemias, various lymphomas and myeloma respectively were registered at our centre from 1st January 2010 to 31st December 2014. Of these, 1178 (63%), 3091 (85%) and 454 (83%) respectively received treatment at our centre. The cumulative probability of 5 year overall survival for patients with acute leukemias, Hodgkin's lymphoma, non-Hodgkin lymphoma and myeloma treated at our centre is 40%, 85%, 78% and 40% respectively. Four hundred and fifteen stem cell transplants were done between 14th November 2007 to 31st December 2014 with 46% being allogeneic and 54% being autologous. The 5 year overall survival of patients with allogenic and autologous transplant was 52% and 63% respectively. Conclusions: This is the largest single centre data on outcomes of various haematological malignancies from India. This real world data identifies areas which need further attention to improve outcomes.

2.
Article in English | IMSEAR | ID: sea-155204

ABSTRACT

Background & objectives: In recent years, brachytherapy involving permanent radioactive seed implantation has emerged as an effective modality for the management of cancer of prostate. 125I-Ocu-Prosta seeds were indigenously developed and studies were carried out to assess the safety of the indigenously developed 125I-Ocu-Prosta seeds for treatment of prostate cancer. Methods: Animal experiments were  performed to assess the likelihood of in vivo release of 125I from radioactive seeds and migration of seeds implanted in the prostate gland of the rabbit. In vivo release of 125I activity was monitored by serial blood sampling from the auricular vein and subsequent measurement of 125I activity. Serial computed tomography  (CT) scans were done at regular intervals till 6 months post implant to assess the physical migration of the seeds. Results: The laser welded seeds maintained their hermeticity and prevented the in vivo release of 125I activity into the blood as no radioactivity was detected during follow up blood measurements. Our study showed that the miniature 125I seeds were clearly resolved in CT images. Seeds remained within the prostate gland during the entire study period. Moreover, the seed displacement was minimal even within the prostate gland. Interpretation & conclusions: Our findings have demonstrated that indigenously developed 125I-Ocu-Prosta seeds may be suitable for application in treatment of prostate cancer.

3.
J Cancer Res Ther ; 2008 Oct-Dec; 4(4): 156-63
Article in English | IMSEAR | ID: sea-111566

ABSTRACT

PURPOSE: To derive and validate an index to correlate the bladder dose with the catheter balloon dose using limited computed tomography (CT) slices. MATERIALS AND METHODS: Applicator geometry reconstructed from orthogonal radiographs were back-projected on CT images of the same patients for anatomy-based dosimetric evaluation. The correlation indices derived using power function of the catheter balloon dose and the bladder volume dose were validated in 31 patients with cervical cancer. RESULTS: There was significant correlation between International Commission on Radiation Units (ICRU)-38 balloon reference dose (Dr) and the dose received by 25% bladder volume (D(25)) (P< 0.0001). Significant correlation was also found between the reference dose of mid-balloon point (D(rm)) and the dose to D(25) (P < 0.0001). Average percentage difference [100 x (observed index - expected index)/ expected index] of observed value of I'25 (index for the dose to D25 bladder with respect to mid-balloon reference point) from that of expected value was 0.52%, when the index was modeled with reference dose alone. Similarly the average percentage difference for I'10cc (index for the dose to 10 cc volume of bladder with respect to mid balloon point) was 0.84%. When this index was modeled with absolute bladder volume and reference dose, standard deviation of the percentage difference between observed and expected index for D(rm) reduced by approximately 2% when compared to D(r). CONCLUSION: For clinical applications, correlation index modeled with reference dose and volume predicts dose to absolute volume of bladder. Correlation index modeled with reference dose gives a good estimate of dose to relative bladder volume. From our study, we found D(rm) to be a better indicator of bladder dose than D(r).


Subject(s)
Biopsy , Brachytherapy/methods , Catheterization , Female , Humans , Prospective Studies , Radiography/methods , Radiometry/methods , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Reproducibility of Results , Scattering, Radiation , Tomography, X-Ray Computed/methods , Urinary Bladder/pathology , Uterine Cervical Neoplasms/diagnosis
SELECTION OF CITATIONS
SEARCH DETAIL